The LambertLab storage infrastructure follows a clear tiered strategy designed to match workload I/O characteristics with optimal backend protocols.


💾 Storage Topology & Workload Mapping

Hold "Alt" / "Option" to enable pan & zoom
graph TD
    subgraph ComputeWorkloads["Kubernetes & Docker Workloads"]
        VMs["KubeVirt VMs<br/>(DC01, Win11, OPNsense)"]
        StatefulPods["Stateful Pods<br/>(Vault, Guac DB, Ntfy, Palworld)"]
        MediaPods["Media Automation<br/>(Sonarr, Radarr, Prowlarr, Jellyfin)"]
        SIEM["Docker ELK Stack & Jellyfin Cache<br/>(Elasticsearch, Host Configs)"]
    end

    subgraph StorageTiers["Multi-Tier Storage Backends"]
        Tier1["Tier 1: SAN Raw iSCSI LUNs<br/>san.lambertlab.us:3260"]
        Tier2["Tier 2: Longhorn Distributed Block<br/>Synchronous 2x/3x NVMe Replication"]
        Tier3["Tier 3: Bulk NFSv4 Pools<br/>/Volume3/isos & /Volume1/data"]
        Tier4["Tier 4: Local NVMe Host Storage<br/>workstation SSD (/usr/share/elasticsearch)"]
    end

    VMs -->|"Direct libiscsi Block Access"| Tier1
    MediaPods -->|"Dedicated Database LUNs"| Tier1
    StatefulPods -->|"CSI Volume Claims / longhorn-retain"| Tier2
    MediaPods -->|"NFS PVC Mounts / RWX"| Tier3
    SIEM -->|"Direct Host Bind Mount"| Tier4

💾 Storage Tiers Matrix

Storage Tier Backend Protocol Host Provider Primary Use Cases Performance Characteristics
Tier 1: SAN iSCSI iSCSI Block Targets TerraMaster F4-425 Plus (san.lambertlab.us) KubeVirt VM boot disks (win11, dc01, opnsense) & Media SQLite DBs (sonarr, radarr, prowlarr) Lowest latency (< 2ms random I/O), direct block access, bypasses overlay filesystem overhead
Tier 2: Distributed Block Longhorn CSI Multi-Node K3s NVMe/SSDs State-backed cluster pods (PostgreSQL, Vault, Ntfy, Palworld) Synchronous 2-3x cross-node replication, automated CSI volume snapshots, longhorn-retain policy
Tier 3: Bulk Network File NFSv4 Pools TerraMaster F4-425 Plus (nas.lambertlab.us) Media libraries (/Volume1/data), ISO repositories (/Volume3/isos), VirtIO drivers High-capacity bulk throughput, multi-client read/write sharing (ReadWriteMany)
Tier 4: Local NVMe Direct Host Filesystem workstation & lenovo Host Disks Docker ELK Stack indices, Jellyfin config/transcode cache, Homarr appdata Extreme write IOPs, zero network latency

🧱 Tier 1: Low-Latency SAN iSCSI Targets

Virtual machines and latency-sensitive media databases require dedicated, high-performance block devices:

  • Target Portal: san.lambertlab.us:3260
  • LUN Architecture:
  • iqn.2026-09.us.lambertlab:win11-boot (LUN 0, 64 GiB) - Windows 11 Enterprise LTSC
  • iqn.2026-09.us.lambertlab:dc01-disk (LUN 0, 80 GiB) - Windows Server 2025 Domain Controller
  • iqn.2026-09.us.lambertlab:opnsense-boot (LUN 0, 40 GiB) - OPNsense Firewall & Routing Gateway
  • iqn.2026-06.us.lambertlab:sonarr-config (LUN 0, 20 GiB) - Sonarr series database & configs
  • iqn.2026-06.us.lambertlab:radarr-config (LUN 0, 20 GiB) - Radarr movie database & configs
  • iqn.2026-06.us.lambertlab:prowlarr-config (LUN 0, 2 GiB) - Prowlarr indexer database & configs
  • Direct Line-Rate Flashing: By using qemu-img convert with native libiscsi user-space drivers, master OS templates are written directly into LUNs at full line rate without needing intermediate 64GB Longhorn scratch volumes or triggering HTTP ingress proxy timeouts.
  • Initiator Resilience & Error Recovery (open-iscsi): To prevent kernel I/O aborts, guest VM crashes, and ext4 emergency_ro journal locks during transient network blips or NAS reboots, all cluster nodes (lenovo, optiplex, opti74, workstation) configure hardened initiator timeouts via ansible/configure-iscsi.yml:
  • node.session.timeo.replacement_timeout = 300: Pauses I/O queues and permits up to 5 minutes of network reconnection grace time before declaring SCSI block devices offline.
  • node.conn[0].timeo.noop_out_interval = 5: Transmits NOP-Out pings every 5 seconds for rapid socket drop detection.
  • node.conn[0].timeo.noop_out_timeout = 5: Bounded 5-second socket timeout triggering proactive TCP session recovery.

🛡️ Tier 2: Longhorn Distributed Block Storage

Critical cluster state (HashiCorp Vault storage, Apache Guacamole's PostgreSQL database, Ntfy message cache) is backed by Longhorn:

  • StorageClass Retention: A custom StorageClass longhorn-retain enforces reclaimPolicy: Retain so that if ArgoCD applications are pruned or re-synced, underlying persistent volumes are never destroyed automatically.
  • Volume Snapshotting: Longhorn schedules automated periodic volume snapshots distributed across healthy control plane nodes.
  • Multipath Daemon Blacklist (multipathd): To prevent host multipath daemons from mistakenly locking Longhorn virtual iSCSI devices (causing MountVolume.SetUp failed: already mounted or mount point busy), worker nodes deploy a devnode "^sd[a-z0-9]+" blacklist to /etc/multipath.conf via ansible/longhorn-reqs.yml per the official Longhorn Knowledge Base: Troubleshooting Volume Mount Failure with multipathd.
# kubernetes/infrastructure/longhorn/storageclass-retain.yaml
apiVersion: storage.k8s.io/v1
kind: StorageClass
metadata:
  name: longhorn-retain
provisioner: driver.longhorn.io
reclaimPolicy: Retain
volumeBindingMode: Immediate
allowVolumeExpansion: true
parameters:
  numberOfReplicas: "2"
  staleReplicaTimeout: "2880"

🚫 Storage Hygiene & Strict Rules

Critical Safety & Operational Rules

  • Prohibited Mounts: Under no circumstances should automated scripts or tools inspect, modify, or run commands against /mnt/blue_drive/, /mnt/black_drive/, or /mnt/media_data/.
  • Never Put Elasticsearch on Network Storage: Elasticsearch indices MUST reside on local workstation NVMe. Staging high-IOPS write indices on 1Gbps network iSCSI causes severe indexing queues and thread pool exhaustion.
  • Lenovo Root SSD Hygiene: Lenovo's primary root SSD (/dev/sda2) is ~116 GB. Never stage 25+ GB VM disk images or ISOs directly on the manager node's root filesystem. Always upload templates directly to the NAS (/Volume3/isos).